công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

  • W2CA-5BA-R/UL

  • AI
    The **W2CA-5BA-R/UL** is a specialized current sensing relay and transducer manufactured by **OMRON**. It is designed to monitor current in a circuit and provide a signal or trigger a relay when the current exceeds or falls below a specific threshold. --- ## 1. Technical Specifications The following table summarizes the core electronic and mechanical parameters for this specific model: | Attribute | Specification | | :--- | :--- | | **Manufacturer** | Omron Automation and Safety | | **Model Type** | W2CA Series Current Sensing Relay | | **Input Current Range** | 1A to 5A (Standard for this variant) | | **Control Voltage** | 100/110/120 VAC (Standard UL rating) | | **Contact Form** | SPDT (Single Pole Double Throw) | | **Reset Method** | Automatic Reset (Standard for -R suffix) | | **Safety Standard** | UL (Underwriters Laboratories) Listed | | **Mounting Type** | Surface or Socket Mounting | --- ## 2. Key Electronic Components The internal architecture of the W2CA-5BA-R/UL consists of several critical functional blocks: ### A. Current Transformer (CT) Interface The device detects AC current through an internal or external current transformer. The **5BA** designation indicates it is tuned for a nominal 5 Amp input, which is the industry standard for CT secondary outputs. ### B. Sensing and Comparison Circuitry * **Comparator:** This electronic stage compares the incoming sensed voltage (proportional to the current) against a user-defined setpoint (the dial on the front). * **Filtering:** Includes low-pass filtering to prevent "nuisance tripping" caused by momentary harmonics or electrical noise. ### C. Relay Output Stage When the threshold is met, the internal electromagnetic relay switches. * **Rated Load:** Typically 5A at 250VAC. * **Mechanical Life:** 10,000,000 operations (minimum). * **Electrical Life:** 100,000 operations (at rated load). --- ## 3. Terminal Configuration While always refer to the specific datasheet provided with the unit, the standard wiring for W2CA units follows this logic: ```markdown Terminal 1 & 2: Power Supply (110VAC) Terminal 3 & 4: Current Input (from CT or Load) Terminal 5, 6, 7: Relay Contacts (Common, NO, NC) ``` --- ## 4. Operational Logic The **-R** in the part number signifies specific behavioral logic: 1. **Detection:** As the current rises above the set point, the relay energizes. 2. **Hysteresis:** There is a built-in differential (usually 3-5%) to prevent the relay from "chattering" if the current hovers exactly at the threshold. 3. **Automatic Reset:** Once the current drops below the threshold (minus the hysteresis), the relay automatically de-energizes without requiring a manual reset button.
    ✨ Follow-up Questions
    • ⤷ How do I calibrate the setpoint for a specific current threshold on this relay?
    • ⤷ Can this relay be used with a 4-20mA transducer signal?
    • ⤷ What is the difference between the W2CA-5BA-R/UL and the W2CA-7BA model?