W2AC-AA1B-R2/Q
AI

The **W2AC-AA1B-R2/Q** is a specific model within the **W2 Series** of signal conditioners manufactured by **M-System**. These devices are primarily used in industrial automation to provide signal isolation, conversion, and amplification.
---
### 1. Technical Specifications Breakdowns
The alphanumeric suffix in the model number defines the specific electronic configuration of the unit:
| Component Code | Description | Specifications |
| :--- | :--- | :--- |
| **W2AC** | **Model Series** | Dual-output signal conditioner (Splitter) |
| **-AA** | **Input/Output 1** | Input: 4–20 mA DC / Output 1: 4–20 mA DC |
| **1** | **Output 2** | Output 2: 4–20 mA DC |
| **-B** | **Power Supply** | 100V – 240V AC (Universal AC power) |
| **-R2** | **Design / Version** | Compact plug-in style with specific terminal layout |
| **-Q** | **Option Code** | Non-standard or special specifications (often tropicalization or specific labels) |
---
### 2. Core Electronic Functions
The device operates as an **Active Signal Splitter**. Its internal circuitry performs three primary electronic tasks:
1. **Isolation (Galvanic):** It provides 2000V AC isolation between the input, output 1, output 2, and power supply. This prevents ground loops from damaging sensitive PLCs or DCS systems.
2. **Signal Conversion:** It takes one analog current loop (4-20mA) and mirrors it into two independent, isolated loops.
3. **Power Regulation:** The internal switching power supply converts the 100-240V AC mains into stabilized DC voltages required for the internal operational amplifiers and optoisolators.
---
### 3. Connection Diagram (General)
The unit typically uses a **socket-mounted** design. The wiring logic follows this pattern:
```text
Input (+) ---- [ Terminal 5 ]
Input (-) ---- [ Terminal 6 ]
Output 1 (+) -- [ Terminal 1 ]
Output 1 (-) -- [ Terminal 2 ]
Output 2 (+) -- [ Terminal 3 ]
Output 2 (-) -- [ Terminal 4 ]
Power (L) ---- [ Terminal 7 ]
Power (N) ---- [ Terminal 8 ]
```
---
### 4. Key Electronic Characteristics
* **Response Time:** Approximately $\le$ 0.5 seconds (0 to 90%).
* **Accuracy:** Within $\pm$0.1% of the span.
* **Load Resistance:**
* Output 1: Up to 750 $\Omega$.
* Output 2: Up to 350 $\Omega$.
* **Insulation Resistance:** 100 M$\Omega$ minimum at 500V DC.
- ⤷
What is the difference between the W2AC and the single-output W2V series?
- ⤷ How does the 'Q' suffix specifically affect the warranty or environmental rating?
- ⤷ Can this unit be used with a 24V DC power source instead of AC?