The **VIPER20ADIP** is a high-performance Offline Switched-Mode Power Supply (SMPS) Primary IC manufactured by STMicroelectronics. It belongs to the VIPer family (Vertical Intelligent Power Miniture) and combines a dedicated PWM controller with a high-voltage Power MOSFET on a single chip.
---
## 1. Key Component Overview
The VIPER20ADIP is designed to handle AC-DC conversion for low-power applications (typically up to 20W) with minimal external components.
### Technical Specifications
| Parameter | Description |
| :--- | :--- |
| **Package** | DIP-8 (Dual In-line Package) |
| **Drain-Source Voltage ($V_{DS}$)** | 700V (High voltage ruggedness) |
| **Switching Frequency** | Up to 200 kHz (Adjustable) |
| **On-Resistance ($R_{DS(on)}$)** | 13.5 $\Omega$ (Typical) |
| **Maximum Output Power** | ~20W (Universal input) |
---
## 2. Pin Configuration (DIP-8)
The device simplifies circuit design by integrating the power transistor and control logic.
| Pin Number | Name | Function |
| :--- | :--- | :--- |
| **1-2** | SOURCE | Internal Power MOSFET Source and Ground reference. |
| **3** | VDD | Power supply for the internal control logic. |
| **4** | COMP | Feedback input for PWM control (Error Amplifier). |
| **5** | OSC | RC network connection to set switching frequency. |
| **6-7-8** | DRAIN | Internal MOSFET Drain; connects to the transformer primary. |
---
## 3. Core Functional Features
### A. Integrated High-Voltage Startup
The IC includes a high-voltage current source that charges the $V_{DD}$ capacitor directly from the Drain pin, eliminating the need for an external startup resistor and improving efficiency.
### B. Internal Protection Circuits
The VIPER20ADIP is "rugged," meaning it includes several failsafes:
* **Thermal Shutdown:** Shuts down if the junction temperature exceeds 170°C.
* **Overcurrent Protection (OCP):** Limits the peak current through the MOSFET to prevent transformer saturation.
* **Undervoltage Lockout (UVLO):** Ensures the chip only operates when the supply voltage is stable.
### C. Burst Mode Operation
In "Standby" or light-load conditions, the IC enters burst mode. This reduces power consumption to meet international energy-saving standards (like Blue Angel or Energy Star).
---
## 4. Typical Application Circuit
The device is commonly used in **Flyback Converter** topologies.
```mermaid
graph LR
AC_Input --> Bridge_Rectifier
Bridge_Rectifier --> Bulk_Capacitor
Bulk_Capacitor --> Transformer_Primary
Transformer_Primary --> VIPER20_Drain
VIPER20_Source --> GND
Optocoupler --> VIPER20_Comp
```
---
- ⤷
What are the main differences between the VIPER20A and the VIPER22A?
- ⤷ How do you calculate the RC values for the OSC pin to set a specific frequency?
- ⤷ What is the maximum power output when used in a 110V vs 230V AC system?