TDC10-1-R
AI

The **TDC10-1-R** is a high-performance, time-delay cartridge fuse manufactured by **Eaton (Bussmann Series)**. It is specifically designed for primary circuit protection in electronic equipment where high surge currents are common.
---
### ## Technical Specifications
The following table summarizes the key electrical characteristics of the TDC10-1-R:
| Parameter | Value |
| :--- | :--- |
| **Rated Current** | 1 Ampere |
| **Voltage Rating (AC)** | 250 Volts |
| **Characteristic** | Time-Delay (Slow-Blow) |
| **Body Material** | Ceramic |
| **Mounting Style** | Holder / Clip (Cartridge) |
| **Dimensions** | 6.3mm x 32mm (1/4" x 1-1/4") |
| **Interrupt Rating** | 35A @ 250Vac |
| **RoHS Compliant** | Yes |
---
### ## Key Electronic Features
#### 1. Time-Delay Mechanism
The "Time-Delay" (also known as "Slow-Blow") characteristic means the fuse can withstand brief, high-current surges (inrush currents) without blowing. This is essential for circuits containing **transformers or motors** that draw significant power only at startup.
#### 2. Ceramic Construction
Unlike glass fuses, the TDC10 series uses a **ceramic tube**. Ceramic provides:
* **High Breaking Capacity:** It can handle higher fault currents without shattering.
* **Arc Suppression:** The internal filler (often silica sand) helps extinguish the electrical arc during a short circuit.
#### 3. Termination and Form Factor
The fuse features nickel-plated brass end caps for high conductivity and corrosion resistance. Its 6.3 x 32mm dimensions are a global standard, making it compatible with a wide variety of panel-mount and PCB-mount fuse holders.
---
### ## Typical Applications
* **Power Supplies:** Protecting the AC input side of switch-mode power supplies.
* **Industrial Controls:** Protecting small motors and solenoids.
* **Consumer Electronics:** Used in high-end audio equipment and appliances where surge protection is required.
---
### ## Part Number Breakdown
* **TDC10:** Series Identifier (6.3 x 32mm Ceramic Time-Delay).
* **1:** Amperage Rating (1A).
* **-R:** RoHS Compliant version.
- ⤷
What is the difference between the TDC10 and the AGC series fuses?
- ⤷ How does the 'Interrupt Rating' affect the safety of this fuse?
- ⤷ Are there specific fuse holders recommended for the 6.3mm x 32mm size?