SES-160-R/E2
AI

The **SES-160-R/E2** is a specific technical configuration typically associated with **SACE Emax 2** series low-voltage power circuit breakers (manufactured by ABB). This designation refers to a high-performance electronic trip unit and its corresponding frame components.
---
## 1. Core Component Breakdown
The "SES" designation usually refers to the **Electronic Trip Unit (Release)** and its specific protection features.
| Part Category | Component Name | Function |
| :--- | :--- | :--- |
| **Electronic Release** | Ekip Touch/Hi-Touch | The "brain" that monitors current and manages tripping logic. |
| **Current Sensors** | Rogowski Coils | Provide high-precision current measurement without saturation issues. |
| **Rating Plug** | SES-160 | Defines the rated current ($I_n$) of the breaker (160A in this case). |
| **Auxiliary Contacts** | E2.2 / E2 Series | Electronic micro-switches that signal the status of the breaker. |
---
## 2. Technical Specifications
The electronic parts of this assembly are designed for digitalization and smart grid integration.
### Protection Functions (LSI/LSIG)
* **L (Overload):** Adjustable trip threshold and time delay.
* **S (Short-time delayed short circuit):** For selective coordination between breakers.
* **I (Instantaneous short circuit):** Immediate trip for high-magnitude faults.
* **G (Ground Fault):** Optional protection against earth leakage.
### Connectivity & Communication
* **Bluetooth:** Allows technicians to configure settings via a smartphone/tablet without physical contact.
* **Power Controller:** Integrated software to manage energy consumption and peak shaving.
* **Measurement:** Internal electronic sensors measure Voltage, Current, Power Factor, and Total Harmonic Distortion (THD).
---
## 3. Electronic Architecture Table
| Feature | Specification |
| :--- | :--- |
| **Power Supply** | Self-powered by current sensors or external 24V DC. |
| **Display Type** | Color touchscreen (on Hi-Touch versions). |
| **Accuracy** | Class 1 (Active Energy) according to IEC 61557-12. |
| **Data Logging** | Internal memory for trip history and event logging. |
---
## 4. Maintenance and Safety
Because these parts are **electronic**, they require specific handling:
1. **Firmware Updates:** The internal "E2" trip units may require periodic firmware updates via the *Ekip Connect* software.
2. **Electrostatic Discharge (ESD):** When replacing the Rating Plug (SES-160), technicians must use ESD protection to avoid damaging the CMOS chips.
- ⤷
How do you calibrate the SES-160 rating plug using Ekip Connect?
- ⤷ What is the difference between the 'Touch' and 'Hi-Touch' electronic releases for Emax 2?
- ⤷ Can the SES-160-R/E2 be integrated into a Modbus or Profibus network?