SBS-22-R
AI

The **SBS-22-R** is a specific model within the **SBS Series** of high-power, industrial-grade **Static Transfer Switches (STS)**. These devices are designed to provide instantaneous switching between two independent AC power sources to ensure uninterruptible power for sensitive electronic equipment.
---
### 1. Core Technical Specifications
The "22" typically refers to the amperage rating (in this case, often 20A or 22A depending on the regional configuration) and "R" signifies a **Rack-mount** form factor.
| Feature | Specification |
| :--- | :--- |
| **Input Channels** | Dual AC Inputs (Source A & Source B) |
| **Switching Time** | < 4ms to 8ms (Typical) |
| **Form Factor** | 1U or 2U 19-inch Rack-mount |
| **Voltage** | 110V/120V or 208V/230V (Model dependent) |
| **Communication** | SNMP, RS232, or Dry Contacts |
---
### 2. Key Electronic Components
The internal architecture of the SBS-22-R consists of several critical electronic subsystems:
#### A. Silicon Controlled Rectifiers (SCRs)
The "Static" in Static Transfer Switch comes from the use of **SCRs** instead of mechanical relays.
* **Function:** They act as high-speed solid-state switches.
* **Advantage:** Unlike mechanical relays that take 20-50ms to switch, SCRs can transfer the load in less than a quarter of a cycle, preventing equipment reboots.
#### B. Control Logic & Microprocessor
This is the "brain" of the unit.
* **Voltage Monitoring:** Constantly samples the waveform of both input sources.
* **Phase Synchronization:** Ensures that the switch only occurs when the two sources are in-phase (or handles the transition safely if they are out of phase).
* **Decision Making:** If Source A drops below a predefined threshold (e.g., -15%), the logic triggers the SCRs to pull from Source B.
#### C. Sensing and Filtering Circuitry
* **Isolation Transformers:** Used in some variants to protect internal logic from power surges.
* **EMI/RFI Filters:** Clean up electrical noise from the input lines before it reaches the connected load.
---
### 3. Functional Logic Diagram
```mermaid
graph LR
A[Source A - Primary] --> S1{SCR Switch 1}
B[Source B - Backup] --> S2{SCR Switch 2}
S1 --> L[Critical Load]
S2 --> L
Logic[Microprocessor] -. Monitor .- A
Logic -. Monitor .- B
Logic -. Control .- S1
Logic -. Control .- S2
```
---
### 4. Operational Indicators
The SBS-22-R usually features an electronic front panel containing:
1. **LED Matrix:** Displays which source is currently active.
2. **Alarm Buzzer:** Triggered during source failure or internal fault.
3. **Manual Override:** Electronic buttons to force a transfer for maintenance.
- ⤷
What is the maximum surge current capacity for the SBS-22-R?
- ⤷ Does this model support remote monitoring via SNMP cards?
- ⤷ How does the SBS-22-R handle out-of-phase transfers between sources?