RL3264L49-R005F
AI

The **RL3264L49-R005F** is a high-precision, low-resistance current sensing resistor, typically manufactured by **Susumu**. It belongs to the RL series, which is known for its excellent performance in power management and current detection circuits.
---
## 1. Component Identification
The part number can be broken down into the following specifications:
| Part Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **RL3264** | Package Size | 3264 Metric (1226 Imperial) |
| **L4** | Terminal Type | 4-Terminal (Kelvin Connection) |
| **9** | Temperature Coefficient | Low TCR (±100ppm/°C or better depending on range) |
| **R005** | Resistance Value | 0.005 $\Omega$ (5 m$\Omega$) |
| **F** | Tolerance | ±1% |
---
## 2. Technical Specifications
This component is designed to handle high current loads while maintaining high accuracy through a specialized terminal layout.
* **Resistance:** 5 m$\Omega$
* **Power Rating:** Typically 1W to 2W (package dependent).
* **Terminal Design:** **Long-side terminal / 4-terminal construction.** This allows for a "Kelvin" measurement, separating the current path from the voltage sensing path to eliminate lead resistance errors.
* **Technology:** Metal foil / Thin film on ceramic substrate.
* **Operating Temperature:** -55°C to +155°C.
---
## 3. Key Applications
Because of its very low resistance and high precision, it is used in:
1. **Battery Management Systems (BMS):** Monitoring charge and discharge cycles in Li-ion batteries.
2. **DC-DC Converters:** Sensing output current for feedback loops.
3. **Inverters:** High-speed current detection in motor control.
4. **Mobile Devices:** Power distribution monitoring in smartphones and laptops.
---
## 4. Why Use a 4-Terminal (Kelvin) Resistor?
In a standard 2-terminal resistor, the solder joints and PCB traces add parasitic resistance. At 5 m$\Omega$, even a tiny amount of trace resistance can cause a 10-20% error.
```text
Standard 2-Terminal: [Current + Sense] ---- [Resistor] ---- [Current + Sense]
Kelvin 4-Terminal: [Current In] ---- [Resistor] ---- [Current Out]
| |
[Voltage Sense] [Voltage Sense]
```
*The voltage is measured directly across the resistive element, bypassing the voltage drop caused by high current flowing through the main leads.*
- ⤷
What is the maximum current capacity for the RL3264L4 series?
- ⤷ How does a Kelvin connection reduce measurement error in mΩ resistors?
- ⤷ What are the recommended PCB footprint dimensions for 3264 metric packages?