PDU-AN2N-R
AI

The **PDU-AN2N-R** is a specific Power Distribution Unit (PDU) model, typically associated with networking and server rack environments. Below is a breakdown of its electronic components, specifications, and design features.
---
## 1. Core Technical Specifications
The "AN2N" series generally refers to basic or metered PDUs designed for high-density power distribution.
| Feature | Description |
| :--- | :--- |
| **Input Voltage** | Typically 100-240V AC (Auto-sensing) |
| **Current Rating** | Usually 16A or 32A depending on the regional plug |
| **Input Plug** | Often IEC-320 C20 or NEMA L6-20P |
| **Output Receptacles** | A mix of IEC C13 (10A) and IEC C19 (16A) outlets |
| **Form Factor** | 0U (Vertical Mount) or 1U/2U (Horizontal) |
---
## 2. Key Electronic Components
### A. Internal Circuitry
* **Busbar System:** Unlike standard power strips that use wires, professional PDUs like the AN2N-R use solid copper busbars. This reduces heat generation and improves conductivity for high-amperage loads.
* **Circuit Breakers:** Integrated thermal-magnetic breakers protect against overloads. The "-R" suffix often indicates a **Resettable** breaker or a **Redundant** configuration.
### B. Monitoring Module (Metered Models)
If the unit is a "Metered" version, it contains:
* **LED Display:** A 3-digit or 4-digit 7-segment display showing real-time Amperage (A).
* **Current Transformer (CT):** An internal sensor that wraps around the main input line to measure current draw without breaking the circuit.
### C. Physical Construction
* **Chassis:** All-metal (Aluminum or Cold-rolled Steel) to provide grounding and electromagnetic interference (EMI) shielding.
* **Socket Material:** High-temperature resistant thermoplastic to prevent melting during sustained high-load operations.
---
## 3. The "-R" Suffix Meaning
In the context of PDU-AN2N-R, the "R" usually signifies specific electronic or physical orientations:
1. **Rackmount/Rear:** Designed for specific mounting at the rear of the cabinet.
2. **Redundancy:** Dual-circuit input in some specialized models.
3. **RoHS Compliant:** Ensuring the electronic solder and components are lead-free.
---
## 4. Wiring Diagram Concept
Internally, the wiring follows a standard parallel distribution to ensure that if one device fails, the others remain powered.
```mermaid
graph LR
Input[AC Input 240V] --> CB[Circuit Breaker]
CB --> Meter[Amperage Meter]
Meter --> Busbar[Copper Busbar]
Busbar --> Outlet1[C13 Outlet]
Busbar --> Outlet2[C13 Outlet]
Busbar --> Outlet3[C19 Outlet]
```
- ⤷
What is the maximum power capacity in Watts for the PDU-AN2N-R?
- ⤷ Does this model support remote IP monitoring via SNMP?
- ⤷ What is the difference between the C13 and C19 outlets on this PDU?