M3A26FCG-R
AI

The **M3A26FCG-R** is a specific part number typically associated with **TDK-Lambda** power modules, specifically within the **CN-A series** of DC-DC converters designed for railway and high-reliability industrial applications.
Below is a detailed breakdown of its electronic characteristics and specifications.
---
## 1. Device Overview
The M3A26FCG-R belongs to the category of **Isolated DC-DC Converters**. These components are designed to convert a wide range of DC input voltages into a regulated, stable DC output while providing galvanic isolation between the input and output stages.
### Key Specifications Table
| Feature | Specification |
| :--- | :--- |
| **Input Voltage Range** | 60V - 160V DC (Standard for Railway) |
| **Output Voltage** | 24V DC (Regulated) |
| **Output Current** | Approx. 4.2A |
| **Output Power** | 100W |
| **Isolation Voltage** | 3.0kVAC (Input to Output) |
| **Package Type** | Quarter Brick (Industry Standard) |
| **Operating Temp** | -40°C to +100°C (Baseplate) |
---
## 2. Electronic Component Breakdown
### A. Power Stage
* **Switching Topology:** Uses high-frequency Pulse Width Modulation (PWM) to achieve high efficiency (typically >88%).
* **Isolation Transformer:** Provides the 3kVAC barrier, protecting the load from input-side surges and noise.
### B. Protection Circuitry
The module integrates several electronic protection features:
1. **Overcurrent Protection (OCP):** Automatically limits output if the load exceeds 105% of rated capacity.
2. **Overvoltage Protection (OVP):** Shuts down the unit if the output voltage rises above a safety threshold.
3. **Thermal Shutdown:** Protects the internal semiconductors from damage if the baseplate exceeds $100^\circ C$.
### C. Control Interface
* **Remote On/Off:** Allows the system to toggle the power supply electronically without breaking the main power lines.
* **Voltage Trim:** An external resistor can be added to adjust the output voltage slightly (e.g., $\pm 10\%$).
* **Remote Sense:** Compensates for voltage drops across long output wires to ensure the load receives exactly 24V.
---
## 3. Physical & Design Considerations
The "FCG" and "R" suffixes in TDK-Lambda nomenclature often refer to specific mounting and compliance features:
* **Baseplate Cooling:** Must be mounted to a heatsink or metal chassis, as it relies on conduction cooling.
* **Railway Compliance:** Designed to meet **EN50155**, which governs electronic equipment used on rolling stock (vibration, shock, and temperature cycles).
---
- ⤷
What are the specific mounting requirements for the M3A26FCG-R baseplate?
- ⤷ How does the Remote Sense feature affect the wiring layout?
- ⤷ What is the recommended external fuse rating for the 110V input line?