công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

  • M2VF2-5W6-R2/CE

  • AI
    The **M2VF2-5W6-R2/CE** is a high-performance **Signal Conditioner (Isolator)** manufactured by **M-System**. It is specifically designed to convert two independent DC input signals into two independent, isolated DC output signals. --- ## 1. Core Technical Specifications The model number breakdown reveals the specific electronic characteristics of this unit: | Feature | Specification | | :--- | :--- | | **Model Series** | M2VF2 (Ultra-slim Signal Conditioner) | | **Input Type (5)** | 4 – 20 mA DC | | **Output 1 Type (W)** | 4 – 20 mA DC | | **Output 2 Type (6)** | 1 – 5 V DC | | **Power Input (R2)** | 24V DC | | **Certification (CE)** | CE Marking compliant | --- ## 2. Key Electronic Components & Design ### A. Dual-Channel Isolation The "VF2" designation indicates a **2-channel** configuration. In this device, the electronics are designed to prevent "ground loops" and noise interference by providing galvanic isolation between: * Input 1 and Output 1 * Input 2 and Output 2 * Power supply and all I/O channels ### B. Signal Conversion Circuitry The internal circuitry utilizes high-precision Operational Amplifiers (Op-Amps) and Analog-to-Digital/Digital-to-Analog conversion (or high-linearity optocouplers) to ensure signal integrity. * **Input Impedance:** Typically 250 $\Omega$ for the 4-20mA input. * **Output Drive:** Output 1 (Current) can usually drive up to 600 $\Omega$ loads, while Output 2 (Voltage) is high-impedance. ### C. Power Management The **R2** designation indicates the unit runs on **24V DC**. Internal electronics include a DC-DC converter to generate the necessary internal voltages for the isolation barrier while maintaining low power consumption (approx. 3W). --- ## 3. Physical & Installation Features * **Form Factor:** Ultra-slim housing (approx. 12.5mm width) to save space on DIN rails. * **Connection:** Tension-clamp or screw terminals (depending on the specific terminal block option). * **Status Indication:** Includes a front-facing LED power indicator to confirm electronic operation. --- ## 4. Summary Table of Performance | Parameter | Value | | :--- | :--- | | **Accuracy** | ±0.1% of span | | **Temp. Coefficient** | ±0.015% per °C | | **Response Time** | $\leq$ 0.5 seconds (0 – 90%) | | **Insulation Resistance** | 100 M$\Omega$ minimum at 500V DC | | **Dielectric Strength** | 2000V AC @ 1 minute |
    ✨ Follow-up Questions
    • ⤷ What is the wiring diagram for the 24V DC power input on this model?
    • ⤷ Does the M2VF2 series support HART signal pass-through?
    • ⤷ What are the specific environmental operating temperature limits for the CE version?