M2RT-61-R2/CE
AI

The **M2RT-61-R2/CE** is a high-precision, industrial-grade temperature transmitter part of the M2 Series by **M-System**. It is designed to convert signals from a Resistance Temperature Detector (RTD) into a standard DC output signal.
---
### 1. General Specifications
This device acts as an interface between field sensors and control systems (PLC/DCS), providing isolation and signal conditioning.
| Feature | Specification |
| :--- | :--- |
| **Model Series** | M2 Series (Mini-M) |
| **Input Type** | RTD (Pt 100, Pt 50, Ni 508.4Ω, etc.) |
| **Output Type** | Current or Voltage (Configurable by suffix) |
| **Power Input** | 100 – 240V AC (Standard for /CE models) |
| **Isolation** | 3-way isolation (input to output to power) |
| **Housing** | Plug-in style base |
---
### 2. Electronic Components & Suffix Breakdown
The alphanumeric code "M2RT-61-R2/CE" defines the internal electronic configuration:
* **M2RT**: RTD Transmitter (Resistance Temperature Detector).
* **6**: **Output 1** - 1 to 5V DC (High impedance).
* **1**: **Output 2** - 4 to 20mA DC (Standard current loop).
* **R2**: **Power Input** - 11 to 27V DC (Note: In some regions, "R" indicates DC power, while "M2" base units vary).
* **CE**: **Certification** - Indicates the unit is built to comply with European CE marking standards for EMC and Safety.
---
### 3. Key Electronic Features
#### A. Signal Conditioning
The internal circuitry linearizes the non-linear resistance changes of an RTD sensor. It utilizes a **burnout protection circuit**, which forces the output to a specific limit (upscale or downscale) if the sensor wire breaks.
#### B. 3-Way Isolation
The device features electronic isolation between:
1. **Input Circuit:** Protects the sensor from electrical noise.
2. **Output Circuit:** Prevents ground loops between the transmitter and the PLC.
3. **Power Supply:** Protects the internal electronics from power surges.
#### C. Calibration Adjustments
The front panel typically includes two multi-turn potentiometers:
* **ZERO:** Adjusts the 0% output point.
* **SPAN:** Adjusts the 100% output point.
---
### 4. Technical Summary Table
| Parameter | Details |
| :--- | :--- |
| **Sampling Rate** | Approx. 200 ms |
| **Accuracy** | ±0.1% of span |
| **Temperature Coefficient** | ±0.015% / °C |
| **Insulation Resistance** | 100 MΩ or more (500V DC) |
| **Dielectric Strength** | 2000V AC @ 1 minute |
- ⤷
How do I wire a 3-wire RTD to the M2RT-61-R2 unit?
- ⤷ What is the specific burnout protection setting for this model?
- ⤷ Can the output signal be changed from voltage to current in the field?