M2RS-CA-R/N
AI

The **M2RS-CA-R/N** belongs to the M2RS series of compact plug-in signal conditioners, typically manufactured by **M-System**. This specific model is an **AC Current Transmitter**, designed to convert an AC current input signal into a standard DC output signal.
Below is a detailed breakdown of its electronic specifications and characteristics.
---
### 1. Model Code Breakdown
| Segment | Identification | Description |
| :--- | :--- | :--- |
| **M2RS** | Series Name | Mini-M series plug-in signal conditioner |
| **CA** | Input Type | AC Current (RMS sensing) |
| **R** | Power Input | 24V DC |
| **N** | Output | 0 – 10V DC (Standard Voltage Output) |
---
### 2. Key Technical Specifications
#### Input Section (AC Current)
* **Input Range:** Typically 0 – 1A AC or 0 – 5A AC (specified at time of order).
* **Input Loss:** ≤ 0.5 VA.
* **Frequency Response:** 40 Hz to 1 kHz (Sine wave).
* **Sensing Method:** True RMS (Root Mean Square), allowing it to handle distorted waveforms accurately.
#### Output Section (DC Voltage)
* **Output Signal:** 0 – 10V DC.
* **Load Resistance:** Minimum 10k $\Omega$.
* **Response Time:** ≤ 0.5 seconds (0 – 90%).
* **Ripple:** ≤ 0.5% p-p.
#### General Characteristics
* **Power Consumption:** Approx. 3W.
* **Isolation:** 4-way isolation (Input to Output to Power to Ground).
* **Isolation Resistance:** ≥ 100 M$\Omega$ with 500V DC.
* **Dielectric Strength:** 2000V AC @ 1 minute (Input to Output to Power to Ground).
---
### 3. Physical & Installation Features
* **Construction:** Plug-in structure with a base socket.
* **Mounting:** DIN rail or surface mounting.
* **Adjustments:** Front-accessible Zero and Span adjustments (±5%).
* **Status Indicator:** Power LED (Green) turns on when the device is energized.
---
### 4. Connection Diagram (General)
The unit typically uses a circular 8-pin or 11-pin base.
```text
Pin Assignment (Example):
1. Output (+)
2. Output (-)
3. Power (L+/+)
4. Power (N-/-)
5. Input (U)
6. Input (V)
```
---
### 5. Applications
* **Current Monitoring:** Converting signals from Current Transformers (CT) to PLC-readable 0-10V signals.
* **Load Measurement:** Monitoring motor currents in industrial automation.
* **Power Management:** Providing feedback for energy management systems.
- ⤷
What are the wiring differences between the 'R' (24V DC) and 'M' (100-240V AC) power models?
- ⤷ How does 'True RMS' sensing differ from 'Average sensing' in this specific transmitter?
- ⤷ What is the maximum allowable input current overload for the M2RS-CA?