The **M2PRU-C7N-R/Q** is a high-performance power supply unit (PSU) module, typically utilized in server environments (such as Inspur systems) or industrial computing clusters. It is designed for high efficiency and redundancy.
---
### 1. Key Technical Specifications
| Parameter | Specification Details |
| :--- | :--- |
| **Model Number** | M2PRU-C7N-R/Q |
| **Power Output** | Typically 1200W - 1300W (depending on input voltage) |
| **Form Factor** | CRPS (Common Redundant Power Supply) / Slimline |
| **Efficiency Rating** | 80 PLUS Platinum or Titanium equivalent |
| **Input Voltage** | 100V - 240V AC (Auto-ranging) |
| **Output Rails** | Main +12V DC and +12Vsb (Standby) |
---
### 2. Core Electronic Components and Functions
The internal circuitry of the M2PRU-C7N-R/Q is divided into several critical stages:
#### A. Input Protection & EMI Filter
* **MOV (Metal Oxide Varistor):** Protects the unit from high-voltage surges.
* **Bridge Rectifier:** Converts AC input into pulsed DC.
* **EMI/EMC Filter:** Uses X/Y capacitors and common-mode chokes to prevent electromagnetic interference from leaking back into the grid.
#### B. Power Factor Correction (PFC)
* **Active PFC Circuit:** Uses a high-frequency switching transistor (MOSFET/GaN) and a large inductor to ensure the input current is in phase with the voltage, maximizing energy efficiency.
#### C. DC-DC Conversion Stage
* **Main Transformer:** Provides galvanic isolation and steps down the high-voltage DC to the required +12V levels.
* **Synchronous Rectification:** Uses MOSFETs instead of diodes on the secondary side to minimize heat loss and maximize efficiency.
#### D. Control and Communication
* **PMBus Interface:** Allows the server's motherboard to monitor real-time data such as power consumption, fan speed, and temperature.
* **MCU (Microcontroller):** Manages the "Hot-Swap" logic and load-sharing protocols when paired with a second PSU.
---
### 3. Safety and Protection Features
The module includes integrated integrated circuits (ICs) that monitor for the following conditions:
* **OCP (Over-Current Protection):** Shuts down if the draw exceeds rated limits.
* **OVP (Over-Voltage Protection):** Prevents damage to the server motherboard if the output voltage spikes.
* **OTP (Over-Temperature Protection):** Features internal thermistors to trigger fan speed increases or emergency shutdowns.
* **SCP (Short-Circuit Protection):** Instantaneous cutoff in case of a direct short.
---
### 4. Physical Interface
The unit uses a "Golden Finger" edge connector. This interface carries:
1. **High-current 12V power pins.**
2. **Return (Ground) pins.**
3. **I2C/PMBus data lines** (SDA, SCL).
4. **Presence signals** (to notify the system the PSU is plugged in).
- ⤷
What are the specific server models compatible with the M2PRU-C7N-R/Q?
- ⤷ How does the PMBus protocol report power efficiency in this specific module?
- ⤷ What is the pinout configuration for the M2PRU series edge connector?