HMS-1-R/
AI

The **HMS-1-R** is a specific model of a **Manual Pull Station**, typically used in fire alarm and emergency systems. Specifically, it is a high-quality, addressable pull station often associated with brands like **Siemens (Cerberus Division)**.
---
### ## Technical Specifications Overview
The "R" in the suffix usually denotes a specific feature set (such as "Reset" capabilities or "Red" housing), and the "HMS" series is known for its integration with intelligent fire alarm control panels.
| Feature | Specification Details |
| :--- | :--- |
| **Device Type** | Addressable Manual Pull Station |
| **Communication Protocol** | Digital (e.g., Siemens H-Series / FDLC) |
| **Operating Voltage** | 18VDC - 31VDC (Loop Powered) |
| **Current Consumption** | ~1mA (Active/Standby) |
| **Installation** | Single-gang or surface mount |
| **Material** | High-impact polycarbonate / Metal Alloy |
---
### ### Key Electronic Components
The HMS-1-R is not a simple mechanical switch; it contains sophisticated circuitry to communicate with a fire panel.
1. **Integrated Microprocessor:**
* The core of the unit is a small microcontroller that handles data encoding and decoding.
* It monitors the state of the internal switch and reports status changes back to the control panel.
2. **Addressing Module:**
* Unlike conventional pull stations, this has an electronic address.
* **Programming:** It is typically programmed using a device like the DPU (Device Programming Unit) to assign a unique ID on the loop.
3. **Status LED:**
* Usually contains a bi-color LED (Red/Green) to indicate "Normal" polling or "Alarm" status.
4. **EEPROM Memory:**
* Internal non-volatile memory stores the device’s unique serial number and its assigned loop address.
5. **Isolation Circuitry:**
* Some versions include built-in short-circuit isolators to ensure that a fault in one station doesn't take down the entire data loop.
---
### ### Wiring Configuration
Because it is an addressable device, it is wired in a **Signaling Line Circuit (SLC)** loop.
```yaml
Terminal 1: Positive (+) Loop In/Out
Terminal 2: Negative (-) Loop In/Out
Terminal 3: Ground (Earth) - For shielding/drain wire
```
---
### ### Operational Logic
1. **Quiescent State:** The microprocessor periodically sends a "Healthy" signal to the fire alarm control panel (FACP).
2. **Activation:** When the lever is pulled, a physical microswitch closes.
3. **Signal Processing:** The microprocessor detects the switch closure and sends an interrupt or a high-priority digital code to the FACP.
4. **Reset:** The device must be mechanically reset (usually with a key or hex tool) to open the switch and allow the FACP to clear the alarm.
- ⤷How do you program the address on an HMS-1-R pull station?
- ⤷ What is the difference between the HMS-1-R and a standard conventional pull station?
- ⤷ Can this device be used with non-Siemens fire alarm control panels?