HAS-40-R/Q
AI

The **HAS-40-R/Q** is a high-performance open-loop current transducer designed by **LEM**. It is primarily used for the electronic measurement of DC, AC, and pulsed currents with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic control).
---
### 1. Key Technical Specifications
The following table summarizes the core electronic characteristics of the HAS-40-R/Q:
| Parameter | Specification |
| :--- | :--- |
| **Primary Nominal Current ($I_{pn}$)** | 40 A |
| **Measuring Range ($I_{pm}$)** | ±120 A (at ±15V) |
| **Supply Voltage ($V_c$)** | ±15 V (±5%) |
| **Output Signal** | Voltage (±4 V at $I_{pn}$) |
| **Accuracy** | ±1% of $I_{pn}$ |
| **Bandwidth** | DC to 50 kHz |
| **Response Time** | < 3 μs |
---
### 2. Internal Electronic Architecture
The device operates on the **Hall Effect** principle. Its internal structure consists of three main components:
1. **Magnetic Core:** A high-permeability ring that concentrates the magnetic flux generated by the primary current.
2. **Hall Generator:** A semiconductor sensor placed in the air gap of the magnetic core. It produces a small voltage proportional to the magnetic flux.
3. **Signal Conditioning Circuit:** An internal amplifier that stabilizes the Hall voltage and converts it into a usable output voltage (typically 4V for the nominal 40A input).
---
### 3. Pin Configuration and Connections
The HAS series typically uses a 4-pin connection layout for the secondary side:
* **Pin 1 (+):** Positive Supply Voltage (+15V)
* **Pin 2 (-):** Negative Supply Voltage (-15V)
* **Pin 3 (M):** Output Signal (Measurement)
* **Pin 4 (0V):** Ground/Common Reference
---
### 4. Core Features and Applications
* **Galvanic Isolation:** Physical separation between the power cable (primary) and the sensor electronics, ensuring safety in high-voltage environments.
* **Low Power Consumption:** Very efficient for battery-operated or sensitive monitoring systems.
* **Applications:**
* Variable speed drives (AC/DC).
* Uninterruptible Power Supplies (UPS).
* Switched Mode Power Supplies (SMPS).
* Battery management systems.
---
- ⤷
What is the difference between open-loop and closed-loop Hall Effect sensors?
- ⤷ How do temperature fluctuations affect the accuracy of the HAS-40-R/Q?
- ⤷ Can this sensor be used with a single-supply 5V microcontroller?