AI

The **FTS-04-R/BL** refers to a specific type of industrial flow sensor, typically a **Calorimetric (Thermal) Flow Switch**. These devices are designed to monitor the flow of liquid media in pipes and trigger a response if the flow rate falls above or below a setpoint.
---
### 1. Key Electronic Components
The device operates on the **calorimetric principle**, which involves no moving parts, increasing its lifespan and reliability.
| Component | Function |
| :--- | :--- |
| **Thermistor (Heated)** | A sensor element that is heated slightly above the ambient temperature of the fluid. |
| **Reference Sensor** | Measures the actual temperature of the medium to compensate for fluctuations. |
| **Signal Converter** | An internal circuit that translates the temperature differential into an electrical signal. |
| **Potentiometer** | Usually found under the cover to allow manual adjustment of the switching point. |
| **LED Indicator** | Provides visual feedback (often Red/Green/Amber) regarding flow status. |
---
### 2. Technical Specifications
While exact specs can vary by manufacturer (often associated with brands like *Kobold* or *Tecfluid*), the standard electronic profile for this series is as follows:
* **Operating Voltage:** Typically 24V DC (±10%) or 230V AC depending on the specific sub-model.
* **Output Type:**
* **Relay (R):** Potential-free changeover contact (SPDT).
* **Transistor:** PNP/NPN options.
* **Switching Function:** Configurable for "normally open" or "normally closed" logic.
* **Response Time:** Generally 2 to 10 seconds (media dependent).
* **Protection Class:** Usually IP65 or IP67 (dust-tight and water-resistant).
---
### 3. Connection and Wiring Logic
The "R/BL" designation often points to specific wiring or housing configurations:
1. **V+ and V-:** Power supply inputs.
2. **Common (COM):** The shared terminal for the relay.
3. **Normally Open (NO):** Closes when flow is detected/exceeds setpoint.
4. **Normally Closed (NC):** Opens when flow is detected.
### 4. Working Principle
The electronics measure the **heat loss** from the heated sensor.
* **No Flow:** Heat stays near the sensor; the temperature difference between the heated sensor and reference sensor is high.
* **Flowing Media:** The liquid "carries away" the heat; the temperature difference drops.
* **The Logic:** The electronic controller detects this drop and triggers the relay once the predefined threshold is reached.
---