FRTD-R-1G-LSLASHQ
AI

Based on the part number **FRTD-R-1G-LS/Q**, this component belongs to a specific family of **RTD (Resistance Temperature Detector) Transmitters** or **Resistance-to-Current Transducers**, often used in industrial automation for precise temperature monitoring.
Below is a breakdown of the electronic specifications and part nomenclature:
### 1. Part Number Breakdown
| Component Segment | Meaning | Description |
| :--- | :--- | :--- |
| **FRTD** | Functional Group | RTD (Resistance Temperature Detector) input module. |
| **R** | Output Type | Typically indicates a **Relay** output or a specific **Resistance** conversion type. |
| **1G** | Range/Configuration | Often represents a specific temperature range or a **1-Channel Galvanic** isolation. |
| **LS** | Connection/Power | Low Signal or specific Loop-powered Supply configuration. |
| **Q** | Quality/Certification | Often denotes "Quick-connect" terminals or specific industrial quality standards. |
---
### 2. Key Electronic Features
This device serves as a bridge between a physical sensor (RTD) and a control system (PLC/DCS).
* **Input Compatibility:** Designed to interface with Platinum RTDs (like Pt100 or Pt1000). It measures the change in resistance as temperature fluctuates.
* **Galvanic Isolation:** The "1G" designation usually implies that the input, output, and power circuits are electrically isolated. This prevents ground loops and protects sensitive PLC inputs from high-voltage surges.
* **Signal Conversion:** It converts the non-linear resistance of the RTD into a standardized linear industrial signal, such as:
* 4-20 mA (current loop).
* 0-10 V DC.
* **Mounting:** Typically designed for **DIN Rail** mounting (35mm) within industrial control panels.
---
### 3. Technical Specifications (Typical)
| Feature | Specification |
| :--- | :--- |
| **Input Type** | 2, 3, or 4-wire Pt100 RTD |
| **Standard Output** | 4-20 mA DC |
| **Supply Voltage** | 24V DC (typical for LS models) |
| **Accuracy** | ±0.1% of span |
| **Response Time** | < 200 ms |
| **Operating Temperature** | -20°C to +60°C |
---
### 4. Application Use Case
This part is used in environments where precise temperature measurement is critical, such as:
1. **Chemical Processing:** Monitoring reactor temperatures.
2. **HVAC Systems:** High-precision air duct monitoring.
3. **Food & Beverage:** Ensuring pasteurization temperatures remain constant.
- ⤷
What is the wiring diagram for a 3-wire RTD connection to this module?
- ⤷ Can this module be used with Pt1000 sensors or only Pt100?
- ⤷ What are the specific isolation voltage ratings for the '1G' version?