FCR-G0-R
AI

The **FCR-G0-R** is a series of high-performance **Magnetic Proximity Sensors** (also known as Reed Switches) commonly used in industrial automation, particularly for cylinder position detection.
### Technical Overview
These sensors are designed to detect the presence of a magnetic field (usually from a magnet mounted on a pneumatic cylinder piston) to trigger a circuit.
| Feature | Specification Details |
| :--- | :--- |
| **Switching Logic** | SPST (Single Pole Single Throw) - Normally Open |
| **Sensor Type** | Reed Switch (Magnetic) |
| **Operating Voltage** | 5V to 240V AC/DC |
| **Switching Capacity** | 10W Max |
| **Switching Current** | 100mA Max |
| **Indicator Lamp** | Red LED (activates when the circuit is closed) |
| **Protection Rating** | IP67 (Dust and water-resistant) |
---
### Key Electronic Components
#### 1. The Reed Switch
The heart of the FCR-G0-R is a glass envelope containing two ferromagnetic blades. When a magnetic field approaches, the blades become polarized and pull together, completing the electrical circuit.
#### 2. LED Indicator Circuit
The "R" in the model often denotes the inclusion of an indicator light. This circuit consists of:
* **LED:** Provides visual feedback of the sensor state.
* **Current-Limiting Resistor:** Protects the LED from burning out at higher voltages (e.g., 24V).
#### 3. Protection Circuitry
To ensure longevity in industrial environments, these sensors typically include:
* **Varistor/Zener Diode:** To protect the reed contacts from voltage spikes caused by inductive loads.
* **Encapsulation:** The internal electronics are potted in epoxy resin to protect against vibration and moisture.
---
### Wiring Configuration
The FCR-G0-R typically uses a **2-wire** configuration. Because it acts as a simple mechanical switch, it can be wired in "Sinking" or "Sourcing" logic depending on the load connection.
```markdown
[Power +] ---- [Load] ---- [Brown Wire] [Sensor] [Blue Wire] ---- [Power -]
```
**Note:** Always ensure a load is present in the circuit. Connecting a 2-wire reed switch directly across a power supply will cause an overcurrent that will weld the internal contacts shut instantly.
- ⤷
What is the difference between the FCR-G0-R and solid-state NPN/PNP sensors?
- ⤷ How do I troubleshoot a sensor that stays permanently closed?
- ⤷ What are the mounting requirements for this specific sensor model?