E5C2-R20KD
AI

The **E5C2-R20KD** is a compact, analog temperature controller manufactured by Omron. It is widely used in industrial applications due to its simplicity, DIN rail mounting capability, and reliability for basic ON/OFF control tasks.
---
## 1. Core Technical Specifications
The "R20KD" suffix defines specific electronic characteristics regarding its input type and output mechanism.
| Feature | Specification |
| :--- | :--- |
| **Control Type** | ON/OFF or PD (Proportional-Derivative) |
| **Input Type** | K-type Thermocouple (Chromel-Alumel) |
| **Output Type** | Relay Contact (SPDT) |
| **Supply Voltage** | 100 to 240 VAC (50/60 Hz) |
| **Contact Rating** | 3A at 250 VAC (Resistive load) |
| **Setting Method** | Analog Dial (Potentiometer) |
| **Accuracy** | ±2% of Full Scale |
---
## 2. Key Electronic Components & Functions
### A. Input Stage (Thermocouple Interface)
The unit is specifically calibrated for **K-type thermocouples**.
* **Cold Junction Compensation:** Internally, the circuit compensates for the ambient temperature at the controller terminals to ensure accurate voltage-to-temperature conversion.
* **High Impedance Buffer:** The input signal from a thermocouple is in millivolts (mV); the internal electronics amplify this signal for processing.
### B. Control Logic (The Comparator)
Unlike digital controllers that use a microprocessor, the E5C2 often uses an **Analog Comparator IC**.
* **Set Point:** Defined by the front-facing potentiometer.
* **Process Value:** The actual temperature reading from the sensor.
* **Hysteresis:** A built-in electronic "gap" (usually around 0.5% of the range) prevents the relay from "chattering" or switching on/off rapidly when the temperature is exactly at the set point.
### C. Output Stage (Electromechanical Relay)
The "R" in the model name indicates a **Relay output**.
* **Component:** An internal miniature SPDT (Single Pole Double Throw) relay.
* **Operation:** When the measured temperature is below the set point, the relay energizes to activate a heater. Once the set point is reached, the relay de-energizes.
### D. Power Supply Section
* **Transformer/Rectifier:** The unit converts the high-voltage AC input (100-240V) into low-voltage DC (typically 12V or 24V) to power the internal logic and the relay coil.
---
## 3. Terminal Connection Diagram
The E5C2-R20KD typically uses an 8-pin circular socket (PF083A).
```text
Pin 1 & 2: Power Supply (100-240 VAC)
Pin 3 & 4: Relay Output (Normally Open / Common)
Pin 7 (+): Thermocouple Positive (Yellow)
Pin 8 (-): Thermocouple Negative (Red)
```
---
## 4. Common Application Use-Cases
* **Packaging Machines:** Controlling heat-seal bars.
* **Ovens/Furnaces:** Maintaining constant temperature where complex PID tuning is not required.
* **Plastic Processing:** Simple mold heating control.
- ⤷
What is the difference between the R20KD and the R20PD models?
- ⤷ How do I wire a 3-wire RTD to this specific K-type controller?
- ⤷ What are the common failure modes for the relay output in the E5C2 series?