CS-B2-02-R-05
AI

The **CS-B2-02-R-05** is a high-precision, industrial-grade current sensor (often identified within the **CS series** of closed-loop Hall effect sensors). These components are designed to measure DC, AC, and pulsed currents with high galvanic isolation.
---
### 1. Key Technical Specifications
The following table summarizes the primary electronic characteristics of the CS-B2-02-R-05:
| Parameter | Value / Description |
| :--- | :--- |
| **Sensor Type** | Closed-loop Hall Effect |
| **Rated Current ($I_{pn}$)** | 200A (Typical for this series code) |
| **Measuring Range** | 0 to ±300A (Peak) |
| **Supply Voltage ($V_c$)** | ±12V to ±15V DC |
| **Output Signal** | Current Output (Conversion ratio 1:2000) |
| **Accuracy** | ±0.5% at Room Temperature |
| **Linearity** | < 0.1% |
| **Frequency Bandwidth** | DC to 100 kHz |
| **Isolation Voltage** | 3kV to 6kV AC (50Hz, 1 min) |
---
### 2. Internal Electronic Components & Operation
The device operates on the **Closed-Loop (Zero Flux)** principle, which involves several internal stages:
1. **Magnetic Core:** A high-permeability soft magnetic ring that concentrates the magnetic field generated by the primary conductor passing through the center.
2. **Hall Element:** Positioned in the air gap of the core. It detects the magnetic flux and converts it into a small voltage.
3. **Secondary Compensation Coil:** A multi-turn winding around the core. An internal amplifier drives a current through this coil to create an opposing magnetic field.
4. **Feedback Circuit:** The internal electronics continuously adjust the secondary current until the net magnetic flux in the core is zero. The secondary current is therefore a perfect scaled replica of the primary current.
---
### 3. Connection Pinout
Typically, these sensors utilize a 3-pin or 4-pin connector (e.g., Molex or terminal block):
* **+V:** Positive Power Supply (e.g., +15V)
* **-V:** Negative Power Supply (e.g., -15V)
* **M / Out:** Measuring Output (Connected to a sampling resistor $R_m$ to ground)
* **0V / Gnd:** Common Ground reference
---
### 4. Application Use Cases
Due to its high precision and fast response time, the CS-B2-02-R-05 is used in:
* **Variable Frequency Drives (VFDs):** Monitoring motor phase current.
* **Uninterruptible Power Supplies (UPS):** Managing battery charge/discharge cycles.
* **Solar Inverters:** Converting DC strings to AC grid power.
* **Welding Equipment:** Maintaining stable output current for arc control.
- ⤷
How do I calculate the sampling resistor (Rm) value for this sensor?
- ⤷ What is the difference between Open-Loop and Closed-Loop Hall sensors?
- ⤷ Can this sensor be powered by a single-sided power supply?