CD10RK1-AB-R
AI

The **CD10RK1-AB-R** is a specific type of coded rotary switch manufactured by C&K (now part of Littelfuse). These components are primarily used to set binary or hexadecimal values manually on a printed circuit board (PCB).
### 1. Component Overview
The CD series consists of 10mm subminiature rotary DIP switches. The specific suffix `RK1-AB-R` defines its mechanical and electrical configuration.
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | C&K / Littelfuse |
| **Series** | CD Series |
| **Code Type** | Binary Coded Decimal (BCD) |
| **Number of Positions** | 10 Positions (0-9) |
| **Actuator Style** | Flush Screw Driver Slot |
| **Mounting Type** | Through-hole (Right Angle) |
---
### 2. Technical Specifications
Understanding the electrical limits is crucial for integrating this part into a circuit:
* **Switching Capacity:** 0.4 VA max @ 20 V AC or DC.
* **Contact Resistance:** 50 mΩ max (initial).
* **Insulation Resistance:** $10^9$ Ω min.
* **Dielectric Strength:** 250 V RMS min.
* **Operating Temperature:** -25°C to 85°C.
* **Process Sealed:** Yes (withstands soldering and cleaning processes).
---
### 3. Pinout and Logic (BCD)
As a **BCD (Binary Coded Decimal)** switch, it converts the physical position of the dial into a 4-bit binary output. When you turn the dial to a number, specific pins are connected to the "Common" (C) pin.
| Position | Pin 1 ($2^0$) | Pin 2 ($2^1$) | Pin 4 ($2^2$) | Pin 8 ($2^3$) |
| :--- | :--- | :--- | :--- | :--- |
| **0** | Open | Open | Open | Open |
| **1** | **Closed** | Open | Open | Open |
| **5** | **Closed** | Open | **Closed** | Open |
| **9** | **Closed** | Open | Open | **Closed** |
---
### 4. Part Number Breakdown (Suffix Meaning)
* **CD10**: 10mm size, 10-position BCD.
* **R**: Right Angle mounting (pins are bent 90 degrees).
* **K**: Actuator type (Flush screw-driver slot).
* **1**: Standard PC thru-hole terminals.
* **AB**: Gold over nickel contact material (ensures high reliability in low-power logic circuits).
* **R**: RoHS Compliant / Tape & Reel packaging (depending on context, usually indicates "RoHS").
### 5. Common Applications
* **Address Setting:** Setting unique IDs for devices on a BUS (like RS-485 or CAN).
* **Configuration:** Selecting operating modes on industrial controllers.
* **Hardware Presets:** Setting timer values or frequency channels on legacy hardware.
---
- ⤷What is the difference between BCD and Hexadecimal coded switches?
- ⤷ How do I wire the common pin to a microcontroller?
- ⤷ Are there surface-mount versions of this switch?