ADM6346-39ARTZ-R7
AI

The **ADM6346-39ARTZ-R7** is a low-power, precision voltage monitoring device manufactured by **Analog Devices**. It is primarily used as a microprocessor supervisory circuit to monitor system voltages and provide a reset signal when necessary.
---
### 1. Key Technical Specifications
Below are the primary electrical characteristics of the component:
| Parameter | Specification |
| :--- | :--- |
| **Reset Threshold** | 3.9V (Nominal) |
| **Output Type** | Open-Drain (Active-Low) |
| **Supply Current** | 1 µA (Typical) |
| **Operating Voltage Range** | 1.0V to 5.5V |
| **Reset Timeout Period** | 100 ms (Minimum) |
| **Package / Case** | SOT-23-3 |
| **Operating Temperature** | -40°C to +85°C |
---
### 2. Functional Description
The ADM6346 is designed to protect electronic systems during power-up, power-down, and brownout conditions.
#### Core Functions:
* **Voltage Monitoring:** It continuously monitors the $V_{CC}$ supply.
* **Reset Assertion:** If $V_{CC}$ falls below the preset threshold (3.9V), the **RESET** output goes low.
* **Power-on Reset:** When power is first applied, the device keeps the system in reset for a fixed period (100ms) after $V_{CC}$ rises above the threshold to ensure the system clock and voltage have stabilized.
* **Glitch Immunity:** It is designed to ignore fast, short-duration transients on the $V_{CC}$ line to prevent "nuisance" resets.
---
### 3. Pin Configuration
The device is housed in a small 3-pin SOT-23 package, making it ideal for space-constrained applications.
| Pin Number | Name | Function |
| :--- | :--- | :--- |
| 1 | **GND** | Ground |
| 2 | **RESET** | Active-Low Output. Open-drain; requires a pull-up resistor. |
| 3 | **Vcc** | Supply Voltage / Monitor Input. |
---
### 4. Implementation Details
Because the output is **Open-Drain**, you must connect a pull-up resistor (typically 10kΩ to 100kΩ) to a voltage source. This allows the reset signal to interface with different logic levels (e.g., pulling up to 3.3V even if the monitored rail is 5V).
```python
# Conceptual Truth Table
# ----------------------
# Condition: Vcc > Threshold (3.9V) -> RESET = High (via Pull-up)
# Condition: Vcc < Threshold (3.9V) -> RESET = Low (GND)
```
---
### 5. Common Applications
* Microprocessor and Microcontroller systems.
* Computers and Controllers.
* Intelligent Instruments.
* Portable/Battery-Powered Equipment (due to the ultra-low 1µA current consumption).
- ⤷What is the significance of the 'R7' suffix in the part number?
- ⤷ Can this device be used to monitor a 3.3V rail
- ⤷ or is it strictly for higher voltages?
- ⤷ What are the advantages of an open-drain reset output compared to a push-pull output?