The part number **8736SDO2V02H31S** refers to a specific configuration of a **Schneider Electric (Square D)** NEMA Reversing Magnetic Starter. These are heavy-duty industrial components used to control the direction and operation of electric motors.
---
### Part Number Breakdown
To understand the electronic and mechanical capabilities, here is a breakdown of the nomenclature:
| Code | Component Segment | Description |
| :--- | :--- | :--- |
| **8736** | Class Type | NEMA Type S Reversing Magnetic Starter. |
| **S** | Size | NEMA Size 2 (Rated for higher horsepower/amperage than Size 0 or 1). |
| **D** | Enclosure | NEMA 1 General Purpose Enclosure (Standard indoor use). |
| **O** | Open/Closed | Open style (usually refers to the internal chassis mount). |
| **2** | Poles | 3-Pole configuration (for 3-phase motors). |
| **V02** | Coil Voltage | 120V AC @ 60Hz / 110V AC @ 50Hz control circuit. |
| **H31** | Overload Relay | Solid-State Overload Relay (Motor Logic) Class 10/20. |
| **S** | Special Feature | Separate control circuit (isolated supply for the coil). |
---
### Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Phase** | 3-Phase |
| **Current Rating** | 45 Amperes |
| **Max Horsepower** | 10 HP @ 200V / 15 HP @ 230V / 25 HP @ 460-575V |
| **Relay Type** | Motor Logic Solid State (Adjustable trip settings) |
| **Control Voltage** | 120 VAC (requires external source or transformer) |
| **Reset Type** | Manual/Automatic (selectable on the relay) |
---
### Key Electronic Components
1. **Reversing Contactors:** Consists of two mechanically interlocked contactors. One manages the forward rotation, and the other manages reverse by swapping two of the three incoming power phases.
2. **Solid-State Overload Relay (H31):** Unlike traditional thermal bimetallic strips, this electronic relay monitors current flow with high precision. It provides protection against phase loss, phase unbalance, and sustained overcurrent.
3. **Mechanical Interlock:** A safety mechanism that physically prevents both the "Forward" and "Reverse" contactors from closing at the same time, which would cause a direct short circuit.
4. **Auxiliary Contacts:** Used for signaling other logic controllers (like a PLC) or for "seal-in" circuits to keep the motor running after a momentary button press.
---
### Wiring Logic Example
For the **V02** coil (120V), the control wiring typically follows this logic:
```mermaid
graph LR
A[120V Hot] --> B[Stop Button]
B --> C[Forward Start]
B --> D[Reverse Start]
C --> E[Forward Coil]
D --> F[Reverse Coil]
E --> G[Neutral]
F --> G
```
- ⤷
What is the adjustment range for the H31 solid-state overload relay in this model?
- ⤷ Can this starter be used with a 24V DC control system instead of 120V AC?
- ⤷ What is the difference between a NEMA Size 2 and a NEMA Size 3 starter?