8736SDO2V02H30S
AI

The part number **8736SDO2V02H30S** refers to a specific configuration of a **Schneider Electric (Square D)** NEMA Reversing Magnetic Starter. These are heavy-duty industrial components used to control the direction and operation of three-phase electric motors.
---
### Part Number Breakdown
| Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **8736** | Class Number | NEMA Reversing Magnetic Starter (Type S) |
| **S** | NEMA Size | Size 2 (Handles up to 45A, 25HP @ 460V) |
| **D** | Enclosure Type | NEMA 1 (General purpose indoor surface mount) |
| **O** | Design Code | Open Type (often indicates internal configuration) |
| **2** | Number of Poles | 3-Pole (standard for 3-phase systems) |
| **V02** | Control Voltage | 120V AC @ 60Hz / 110V AC @ 50Hz coil |
| **H30S** | Overload Relay | Motor Logic™ Solid-State Overload Relay (Class 10/20) |
---
### Key Technical Specifications
#### 1. Reversing Capability
The unit consists of two contactors mechanically and electrically interlocked. This allows the motor to run in both **Forward** and **Reverse** directions by swapping two phases of the incoming power, while preventing both contactors from closing simultaneously (which would cause a short circuit).
#### 2. Solid-State Overload Protection (H30S)
Unlike traditional thermal melting alloy heaters, the **H30S** designation indicates a **Motor Logic™** solid-state overload relay.
* **Adjustable Trip Class:** Typically supports Class 10 and Class 20.
* **Phase Loss Protection:** Automatically trips if one of the three phases is lost.
* **Wide Current Range:** Allows for fine-tuning the trip current to match the specific motor Nameplate FLA (Full Load Amps).
#### 3. Power Ratings (NEMA Size 2)
| Voltage | Max Horsepower (HP) |
| :--- | :--- |
| 200 - 230V AC | 15 HP |
| 460 - 575V AC | 25 HP |
---
### Electronic & Physical Features
* **Coil (V02):** The electromagnetic coil requires a 120V AC signal to pull the contacts closed. This is often provided via a control transformer or a separate control circuit.
* **Auxiliary Contacts:** Usually equipped with one normally open (N.O.) holding circuit contact per contactor.
* **Durability:** Designed for high-cycle applications (millions of operations) and harsh industrial environments.
---
- ⤷
What is the difference between NEMA Size 1 and Size 2 for this starter series?
- ⤷ How do I wire the control circuit for the 120V V02 coil?
- ⤷ Can the H30S solid-state relay be adjusted for different motor FLA ranges?