| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PIC18F4331T-E/ML bảng dữ liệu(PDF) 253 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC18F4331T-E/ML bảng dữ liệu(HTML) 253 Page - Microchip Technology |
|
253 / 392 page ![]() 2010 Microchip Technology Inc. DS39616D-page 253 PIC18F2331/2431/4331/4431 21.9 A/D Conversions Figure 21-3 shows the operation of the A/D Converter after the GO/DONE bit has been set and the ACQT<2:0> bits are cleared. A conversion is started after the following instruction to allow entry into Sleep mode before the conversion begins. The internal A/D RC oscillator must be selected to perform a conversion in Sleep. Figure 21-4 shows the operation of the A/D Converter after the GO/DONE bit has been set, the ACQT<3:0> bits are set to ‘010’ and a 4 TAD acquisition time is selected before the conversion starts. Clearing the GO/DONE bit during a conversion will abort the current conversion. The resulting buffer loca- tion will contain the partially completed A/D conversion sample. This will not set the ADIF flag, therefore, the user must read the buffer location before a conversion sequence overwrites it. After the A/D conversion is completed or aborted, a 2TAD wait is required before the next acquisition can be started. After this wait, acquisition on the selected channel is automatically started. FIGURE 21-3: A/D CONVERSION TAD CYCLES (ACQT<2:0> = 000, TACQ = 0) FIGURE 21-4: A/D CONVERSION TAD CYCLES (ACQT<3:0> = 0010, TACQ = 4 TAD) Note: The GO/DONE bit should NOT be set in the same instruction that turns on the A/D. TAD1 TAD2 TAD3 TAD4 TAD5 TAD6 TAD7 TAD8 TAD11 TAD9 TAD10 GO/DONE bit cleared on the rising edge of Q1 after the first Q3 Conversion Starts b2 b8 b7 b6 b5 b4 b3 b9 b1 b0 following TAD11 and result buffer is loaded.(1) GO/DONE bit is set and holding cap is disconnected from analog input Note 1: Conversion time is a minimum of 11 TAD + 2 TCY and a maximum of 11 TAD + 6 TCY. A/D Triggered (Holding capacitor is disconnected) 1 2 3 4 TACQT Cycles Automatic Acquisition Time TAD1 TAD2 TAD3 TAD4 TAD5 TAD6 TAD7 TAD8 TAD11 TAD9 TAD10 GO/DONE bit cleared on the rising edge of Q1 after the first Q3 Conversion Starts b2 b8 b7 b6 b5 b4 b3 b9 b1 b0 following TAD11 and result buffer is loaded.(1) TAD Cycles Note 1: In Continuous modes, next conversion starts at the end of TAD12. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |