| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
H8S/2111B bảng dữ liệu(PDF) 303 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
H8S/2111B bảng dữ liệu(HTML) 303 Page - Renesas Technology Corp |
|
303 / 582 page ![]() Rev. 1.00, 05/04, page 269 of 544 Yes <End> [1] No Initialization Start reception [2] No Yes Read RDRF flag in SSR [4] [5] Clear RE bit in SCR to 0 Error processing (Continued below) [3] Read receive data in RDR and clear RDRF flag in SSR to 0 No Yes ORER = 1 RDRF = 1 All data received? Read ORER flag in SSR <End> Error processing Overrun error processing Clear ORER flag in SSR to 0 [3] [1] SCI initialization: The RxD pin is automatically designated as the receive data input pin. [2] [3] Receive error processing: If a receive error occurs, read the ORER flag in SSR, and after performing the appropriate error processing, clear the ORER flag to 0. Transfer cannot be resumed if the ORER flag is set to 1. [4] SCI status check and receive data read: Read SSR and check that the RDRF flag is set to 1, then read the receive data in RDR and clear the RDRF flag to 0. Transition of the RDRF flag from 0 to 1 can also be identified by an RXI interrupt. [5] Serial reception continuation procedure: Figure 12.19 Sample Serial Reception Flowchart 12.6.5 Simultaneous Serial Data Transmission and Reception (Clocked Synchronous Mode) Figure 12.20 shows a sample flowchart for simultaneous serial transmit and receive operations. After initializing the SCI, the following procedure should be used for simultaneous serial data transmit and receive operations. To switch from transmit mode to simultaneous transmit and receive mode, check that the SCI has finished transmission and the TDRE and TEND flags in SSR are set to 1, clear the TE bit in SCR to 0, and then set the TE and RE bits to 1 simultaneously with a single instruction. To switch from receive mode to simultaneous transmit and receive mode, check that the SCI has finished reception, and clear the RE bit to 0. Then after checking that the RDRF bit in SSR and receive error flags (ORER, FER, and PER) are cleared to 0, set the TE and RE bits to 1 simultaneously with a single instruction. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |