| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
H8S/2111B bảng dữ liệu(PDF) 354 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
H8S/2111B bảng dữ liệu(HTML) 354 Page - Renesas Technology Corp |
|
354 / 582 page ![]() Rev. 1.00, 05/04, page 320 of 544 12. The IRIC flag is set to 1 in either of the following cases. At the fall of the 8th receive clock pulse for one frame SCL is automatically fixed low in synchronization with the internal clock until the IRIC flag is cleared. At the rise of the 9th receive clock pulse for one frame The IRTR and ICDRF flags are set to 1, indicating that one frame of data has been received. The master device outputs the receive clock continuously to receive the next data. 13. Read the IRTR flag in ICSR. If the IRTR flag is 0, execute step [14] to clear the IRIC flag to 0 to release the wait state. If the IRTR flag is 1 and data reception is complete, execute step [15] to issue the stop condition. 14. If IRTR flag is 0, clear the IRIC flag to 0 to release the wait state. Execute step [12] to read the IRIC flag to detect the end of reception. 15. Clear the WAIT bit in CMR to cancel the wait mode. Then, clear the IRIC flag. Clearing of the IRIC flag should be done while WAIT = 0. (If the WAIT bit is cleared to 0 after clearing the IRIC flag and then an instruction to issue a stop condition is executed, the stop condition may not be issued correctly.) 16. Read the last ICDR receive data. 17. Clear the BBSY bit and SCP bit to 0 in ICCR. This changes SDA from low to high when SCL is high, and generates the stop condition. SDA (master output) SDA (slave output) 2 1 2 1 4 36 58 79 Bit 7 Bit 6 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 IRIC IRTR ICDR SCL (master output) Data 1 [1] TRS cleared to 0 IRIC cleard to 0 [6] IRIC clear [5] ICDR read (Data 1) [6] IRIC clear (to end wait insertion) User processing Bit 5 Bit 4 Bit 3 5 4 3 9 Data 1 Data 2 [3] [3] A [2] ICDR read (dummy read) Master tansmit mode Master receive mode A [4]IRTR=0 [4] IRTR=1 Figure 13.15 Example of Master Receive Mode Operation Timing (MLS = ACKB = 0, WAIT = 1) |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |