160 / 210 page ![]() 160 AT8xC51SND1C 4109E–8051–06/03 Bit Rate The bit rate can be selected from seven predefined bit rates or from a programmable bit rate generator using the SSCR2, SSCR1, and SSCR0 control bits in SSCON (see Table 142). The predefined bit rates are derived from the peripheral clock (F PER) issued from the Clock Controller block as detailed in section "Oscillator", page 12, while bit rate generator is based on timer 1 overflow output. Note: 1. These bit rates are outside of the low speed standard specification limited to 100 kHz but can be used with high speed TWI components limited to 400 kHz. Master Transmitter Mode In the master transmitter mode, a number of data Bytes are transmitted to a slave receiver (see Figure 125). Before the master transmitter mode can be entered, SSCON must be initialized as follows: SSCR2:0 define the serial bit rate (see Table 135). SSPE must be set to enable the con- troller. SSSTA, SSSTO and SSI must be cleared. The master transmitter mode may now be entered by setting the SSSTA bit. The TWI logic will now monitor the TWI bus and generate a START condition as soon as the bus becomes free. When a START condition is transmitted, the serial interrupt flag (SSI bit in SSCON) is set, and the status code in SSSTA is 08h. This status must be used to vector to an interrupt routine that loads SSDAT with the slave address and the data direction bit (SLA+W). The serial interrupt flag (SSI) must then be cleared before the serial transfer can continue. When the slave address and the direction bit have been transmitted and an acknowl- edgment bit has been received, SSI is set again and a number of status code in SSSTA are possible. There are 18h, 20h or 38h for the master mode and also 68h, 78h or B0h if the slave mode was enabled (SSAA = logic 1). The appropriate action to be taken for each of these status code is detailed in Table 136. This scheme is repeated until a STOP condition is transmitted. SSPE and SSCR2:0 are not affected by the serial transfer and are not referred to in Table 136. After a repeated START condition (state 10h) the controller may switch to the master receiver mode by loading SSDAT with SLA+R. Table 135. Serial Clock Rates SSCRx Bit Frequency (kHz) F PER Divided By 210 F PER = 6 MHz F PER = 8 MHz F PER = 10 MHz 0 0 0 47 62.5 78.125 256 0 0 1 53.5 71.5 89.3 224 0 1 0 62.5 83 104.2(1) 192 0 1 1 75 100 125(1) 160 1 0 0 12.5 16.5 20.83 960 1 0 1 100 133.3(1) 166.7(1) 120 110 200(1) 266.7(1) 333.3(1) 60 1 1 1 0.5 < ⋅ < 125(1) 0.67 < ⋅ < 166.7(1) 0.81 < ⋅ < 208.3(1) 96 ⋅ (256 – reload value Timer 1) SSCR2 SSPE SSSTA SSSTO SSI SSAA SSCR1 SSCR0 Bit Rate 1 0 0 0 X Bit Rate Bit Rate |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |