110 / 176 page ![]() µPSD325X DEVICES 110/176 Power-down Instruction and Power-up Mode Power-up Mode. The PSD MODULE internal logic is reset upon Power-up to the READ Mode. Sector Select (FS0-FS7 and CSBOOT0- CSBOOT3) must be held Low, and WRITE Strobe (WR, CNTL0) High, during Power-up for maximum security of the data contents and to remove the possibility of a byte being written on the first edge of WRITE Strobe (WR, CNTL0). Any WRITE cycle initiation is locked when VCC is below VLKO. READ Under typical conditions, the MCU may read the primary Flash memory or the secondary Flash memory using READ operations just as it would a ROM or RAM device. Alternately, the MCU may use READ operations to obtain status information about a Program or Erase cycle that is currently in progress. Lastly, the MCU may use instructions to read special data from these memory blocks. The following sections describe these READ functions. READ Memory Contents. Primary Flash memo- ry and secondary Flash memory are placed in the READ Mode after Power-up, chip reset, or a Reset Flash instruction (see Table 85, page 109). The MCU can read the memory contents of the pri- mary Flash memory or the secondary Flash mem- ory by using READ operations any time the READ operation is not part of an instruction. READ Primary Flash Identifier. The primary Flash memory identifier (E7h) is read with an in- struction composed of 4 operations: 3 specific WRITE operations and a READ operation (see Ta- ble 85). During the READ operation, Address Bits A6, A1, and A0 must be ’0,’ ’0,’ and ’1,’ respective- ly, and the appropriate Sector Select (FS0-FS7) must be High. READ Memory Sector Protection Status. The primary Flash memory Sector Protection Status is read with an instruction composed of 4 operations: 3 specific WRITE operations and a READ opera- tion (see Table 85). During the READ operation, address Bits A6, A1, and A0 must be ’0,’ ’1,’ and ’0,’ respectively, while Sector Select (FS0-FS7 or CSBOOT0-CSBOOT3) designates the Flash memory sector whose protection has to be veri- fied. The READ operation produces 01h if the Flash memory sector is protected, or 00h if the sector is not protected. The sector protection status for all NVM blocks (primary Flash memory or secondary Flash mem- ory) can also be read by the MCU accessing the Flash Protection registers in PSD I/O space. See the section entitled “Flash Memory Sector Pro- tect,” page 115, for register definitions. Reading the Erase/Program Status Bits. The Flash memory provides several status bits to be used by the MCU to confirm the completion of an Erase or Program cycle of Flash memory. These status bits minimize the time that the MCU spends performing these tasks and are defined in Table 86, page 111. The status bits can be read as many times as needed. For Flash memory, the MCU can perform a READ operation to obtain these status bits while an Erase or Program instruction is being executed by the embedded algorithm. See the section entitled “Programming Flash Memory,” page 112, for de- tails. Data Polling Flag (DQ7). When erasing or pro- gramming in Flash memory, the Data Polling Flag Bit (DQ7) outputs the complement of the bit being entered for programming/writing on the DQ7 Bit. Once the Program instruction or the WRITE oper- ation is completed, the true logic value is read on the Data Polling Flag Bit (DQ7) (in a READ opera- tion). s Data Polling is effective after the fourth WRITE pulse (for a Program instruction) or after the sixth WRITE pulse (for an Erase instruction). It must be performed at the address being programmed or at an address within the Flash memory sector being erased. s During an Erase cycle, the Data Polling Flag Bit (DQ7) outputs a '0.' After completion of the cycle, the Data Polling Flag Bit (DQ7) outputs the last bit programmed (it is a '1' after erasing). s If the byte to be programmed is in a protected Flash memory sector, the instruction is ignored. s If all the Flash memory sectors to be erased are protected, the Data Polling Flag Bit (DQ7) is reset to '0' for about 100µs, and then returns to the previous addressed byte. No erasure is performed. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |