| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
STR720 bảng dữ liệu(PDF) 351 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STR720 bảng dữ liệu(HTML) 351 Page - STMicroelectronics |
|
351 / 401 page ![]() STR720 - MISCELLANEA REGISTERS (GCR - CGC - AHB_ERR) 351/401 24 MISCELLANEA REGISTERS (GCR - CGC - AHB_ERR) 24.1 Introduction This section collects the registers setting all the aspects of STR720 which can be configured by software. Hereafter the specification of A-GCR, S-GCR and CGC blocks can be found, allowing application software to select between different functional options, to check the status of relevant internal configuration signals and to control clock and reset lines of most of internal peripherals. At the end of this section, the specification of the AHB error detection block is reported. 24.2 A-GCR Block description This block contains the configuration settings related to the peripherals connected to the A-APB subsystem. A-APB Global Configuration Register 1 (AGCR1) Address: 0xE000_1000 Reset value: 0x0000 Bit 15:3 = Reserved. These bits must be always written to 0. Bit 2 = ADC_STOP: ADC STOP mode This bit can temporarily stop sampling operation of the Analog to Digital Converter block without affecting the programming of its configuration registers. 0: ADC is operating normally. 1: ADC operations are stopped. Bit 1 = Reserved. This bit must be always written to 0. Bit 0 = ADC_OFF: ADC analog section OFF This bit controls the activation of the whole analog section contained in the ADC module, where also internal current references used for clock pad are generated. When this bit is set to ‘1’ all the analog circuitry in the ADC module is switched off. 0: ADC analog section is switched on. 1: ADC analog section is switched off. Note Be careful on setting ADC_OFF bit since it switches off the current references used by clock pad and in this condition no clock signal can be supplied to the device through CLK pad. If this configuration is required for extreme power reduction purposes, STR720 must be put in SLOW mode before setting ADC_OFF bit, otherwise the system will stop responding up to the next hardware reset event. 15 14 13 12 11 10 9 8 765432 1 0 Reserved ADC_ STOP Res. ADC_ OFF -rw - rw |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |